Summary
When a prerequisite is marked as hidden from the installation list, then the execution of the prerequisite will use the prerequisite's silent command line.Synopsis
If a prerequisite is configured to be hidden from the installation list, when the prerequisite executes, the prerequisite's silent command line will be used instead of the regular command line. This is true regardless of whether the prerequisite is installed before feature selection (a setup prerequisite) or is associated with a feature (a feature prerequisite).Discussion
A prerequisite can be configured to be hidden from the installation list. This configuration is done by opening the prerequisite in the Prerequisite Editor, selecting the Behavior tab and checking the box labeled 'The prerequisite should be hidden from the installation list'.
When a prerequisite is marked as hidden from the installation list, then the execution of the prerequisite will use the prerequisite's silent command line.
The silent command line can be viewed in the Prerequisite Editor under the Application to Run tab in the text box under the label 'Specify the command line for the application when the setup is running in silent mode'.
The command line labeled 'Specify the command line for the application when the setup is running in silent mode' will be used if one or more of the following is true:
-
The main installation is run in silent mode
-
The prerequisite's behavior is configured to be hidden from the installation list
Also note, if the silent command line is left blank and one of the above is true, the prerequisite will run with an empty command line. Therefore, it is recommended if the text box labeled 'Specify the command line for the application' has a value, then the text box labeled 'Specify the command line for the application when the setup is running in silent mode' also has a value. This ensures that if an user ever runs the installation silently, a proper command line will be used when executing the prerequisite.
Additional Information
Feature prerequisites can be used in Basic MSI or Web project types.
More detail on hiding the prerequisite from the installation list can be found in the InstallShield Help Library at:
More detail on specifying a prerequisite's command line can be found in the InstallShield Help Library at:
Was this helpful?
Related Articles
Verbosely Log a Command Line Build 9Number of Views Adminstudio Command Line Parameters 13Number of Views Installation of a Basic MSI Setup in Non-User Interface Mode(Reduced UI, Basic UI, No UI - Means a Silent Installation Tha… 10Number of Views Using AdminStudio Repackager Command line options to build .ism and .msi from existing .irp file 8Number of Views InstallShield Setup.exe Command Line Parameters 28Number of Views
Revenera Assistant
Online
Hi, I am Reva - Ask me anything.
Updates
No new updates
Chat
Home
Updates
/**/
Thanks for the feedback!
Your feedback has been saved.Rate this response:
1
2
3
4
5
Add Additional feedback ( Optional )
0/240
English
English
Language changed successfully
Something went wrong
Email sent successfully
Something went wrong
Case create successfully
Are you sure you want to cancel
the case creation?
Please select a product to submit the case.
Please select a product version to submit the case.
0/255
Upload Attachment
File Upload
Maximum file
size allowed is 3 MB.
File type
not supported.
Supported file types:
Documents (.txt, .doc, .docx, .pdf), Images (.jpg, .png), Comma Separated Files
(.csv) Speadsheets (.xlsx, .xls)
Are you sure you want to cancel the case creation?
Case closed successfully
File Upload
Maximum file size allowed is 3 MB.
File type not supported.
Supported file types:
Documents (.txt, .doc, .docx, .pdf), Images (.jpg, .png), Comma Separated Files
(.csv) Speadsheets (.xlsx, .xls)
Are you sure you want to close this case
| Products | Region | Phone Numbers |
|---|---|---|
| FlexNet Operations FlexNet Embedded FlexNet Publisher FlexNet Connect FlexNet Code Insight InstallAnywhere InstallShield |
North America * |
+1 630-332-2513 (toll) +1 877-279-2853 (toll-free in North America) |
| Europe * |
+44 1925 944367 (toll) +44 800 047 8642 (toll-free in Europe) |
|
| Japan * | +81 3-4540-5335 (select option 2) | |
| Australia * |
+61 3 9895 2177 +61 1800 560 603 (toll-free in Australia) |
|
|
Usage Intelligence (formerly
Revulytics) Compliance Intelligence |
Please use the Case Portal to submit your support ticket or reach out to your Revenera contact. | |
File Upload
Maximum file
size allowed is 3 MB.
File type
not supported.
Supported file types:
Documents (.txt, .doc, .docx, .pdf), Images (.jpg, .png), Comma Separated Files
(.csv) Speadsheets (.xlsx, .xls)
Revenera Assistant
© 2026 Flexera Software. All Rights Reserved.
Case id: 00001065
Activity: Status change: 2 hours ago