Summary
This article discusses how to configure InstallAnywhere variables to be encrypted and to register the InstallAnywhere variables to be recorded in a response file.Synopsis
This article discusses how to configure InstallAnywhere variables to be encrypted and to register the InstallAnywhere variables to be recorded in a response file.Discussion
1. Navigate to Project > Variables.2. Click the Configure button.
3. Click the Add button.
4. Enter the InstallAnywhere variable name for the variable to be encrypted (TESTVAR, for example).
5. Select the Encrypt Variable Value from the dropdown option.
7. Configure the Action to set your InstallAnywhere variable to a value.
Note: This Custom Code snippet gets a handle on the ReplayVariableService then calls the register method off of the ReplayVariableService object reference to register the InstallAnywhere variable to be recorded in the response file.
10. Configure the Action to execute the Custom Code Action.
12. Build the project.
13. Run the installer and pass the -r parameter to record a response file with the path and name of the response file to be recorded:
For example: install.exe -r C:\Users\JoeSmith\Desktop\installer.properties
Additional Information
Hiding or Encrypting an InstallAnywhere Variable Value.For information about Encrypting variable values, click here.
Was this helpful?
Related Articles
Get User Input Console Fails to Write Additional Numbered Results Variables to Response File 9Number of Views How to Have a Response File's Default Variable Values not Overwritten During Install 3Number of Views Output InstallAnywhere Variables 5Number of Views Register InstallAnywhere from the Command-line 3Number of Views How to Register InstallAnywhere (Versions 8.0 - 2010) 11Number of Views
Revenera Assistant
Online
Hi, I am Reva - Ask me anything.
Updates
No new updates
Chat
Home
Updates
/**/
Thanks for the feedback!
Your feedback has been saved.Rate this response:
1
2
3
4
5
Add Additional feedback ( Optional )
0/240
English
English
Language changed successfully
Something went wrong
Email sent successfully
Something went wrong
Case create successfully
Are you sure you want to cancel
the case creation?
Please select a product to submit the case.
Please select a product version to submit the case.
0/255
Upload Attachment
File Upload
Maximum file
size allowed is 3 MB.
File type
not supported.
Supported file types:
Documents (.txt, .doc, .docx, .pdf), Images (.jpg, .png), Comma Separated Files
(.csv) Speadsheets (.xlsx, .xls)
Are you sure you want to cancel the case creation?
Case closed successfully
File Upload
Maximum file size allowed is 3 MB.
File type not supported.
Supported file types:
Documents (.txt, .doc, .docx, .pdf), Images (.jpg, .png), Comma Separated Files
(.csv) Speadsheets (.xlsx, .xls)
Are you sure you want to close this case
| Products | Region | Phone Numbers |
|---|---|---|
| FlexNet Operations FlexNet Embedded FlexNet Publisher FlexNet Connect FlexNet Code Insight InstallAnywhere InstallShield |
North America * |
+1 630-332-2513 (toll) +1 877-279-2853 (toll-free in North America) |
| Europe * |
+44 1925 944367 (toll) +44 800 047 8642 (toll-free in Europe) |
|
| Japan * | +81 3-4540-5335 (select option 2) | |
| Australia * |
+61 3 9895 2177 +61 1800 560 603 (toll-free in Australia) |
|
|
Usage Intelligence (formerly
Revulytics) Compliance Intelligence |
Please use the Case Portal to submit your support ticket or reach out to your Revenera contact. | |
File Upload
Maximum file
size allowed is 3 MB.
File type
not supported.
Supported file types:
Documents (.txt, .doc, .docx, .pdf), Images (.jpg, .png), Comma Separated Files
(.csv) Speadsheets (.xlsx, .xls)
© 2026 Flexera Software. All Rights Reserved.
Case id: 00001065
Activity: Status change: 2 hours ago