Summary
This article describes the error of "An error occurred loading data from the beacon service: The data is invalid" and how to avoid the error.
Synopsis
Users may see the error of "An error occurred loading data from the beacon service: The data is invalid" when launching a beacon.
In the "inventorybeaon.log", you will see the following error.
2017-06-09 12:38:10,936 [Beacon.MainForm ] [ERROR] Failed to load data from service. Exiting application.
System.Security.Cryptography.CryptographicException: The data is invalid.
at System.Security.Cryptography.ProtectedData.Unprotect(Byte[] encryptedData, Byte[] optionalEntropy, DataProtectionScope scope)
at ManageSoft.Compliance.Security.Cryptography.DPAPIAESDataProtectScheme.Init(Byte[] entropy, Byte[] key)
at Flexera.Beacon.Data.BusinessImport.DDIJob.LoadAttributesFromImportNode(XElement node)
at Flexera.Beacon.Data.BusinessImport.DDIJob.LoadAttributesFromImportNode(String ddiFile)
at Flexera.Beacon.Data.BusinessImport.DDIJobCollection.Load(String path)
at Flexera.Beacon.Data.BusinessImport.DDIJobCollection..ctor(String path)
at ManageSoft.Compliance.Beacon.Data.DataStore.LoadConnections()
at ManageSoft.Compliance.Beacon.Data.DataStore..ctor(IBeaconDataLayer beaconDataLayer)
at ManageSoft.Compliance.Beacon.MainForm..ctor()
Discussion
This error happens when the encrypted connection string cannot be decrypted. When the serial number or hardware information of the beacon machine is changed, the encryption is no longer valid for the machine and can cause the error.
1) Move all business adapters from "C:\ProgramData\Flexera Software\Beacon\BusinessAdapter" to a different directory and then try to open the beacon UI.
2) If it opens without any error, you can confirm the problem came from one of the moved adapters.
3) Identify the problematic adapter by putting the adapters back one by one to the original folder.
4) Remove the connection string from the adapter XML and re-configure the connection string.
Related Articles
Red error bar when viewing/exporting data from the web UI after importing date custom property values in an invalid format… 13Number of Views An error occurred while loading the Software Vulnerability Manager Plugin 10Number of Views Error may appear in beacon-services.log files: "Error occurred while saving the log file. Exception: {0} Stream does not s… 15Number of Views VMware data is imported from both ILMT and inventory gathered by a beacon may result in multiple inventory device records … 4Number of Views "Populate userAppUsage from API" step reading data from Flexera One SaaS Manager may fail with error: API call failed afte… 15Number of Views
Hi, I am Reva - Ask me anything.
No new updates
Thanks for the feedback!
Your feedback has been saved.Rate this response:
Add Additional feedback ( Optional )
Are you sure you want to cancel
the case creation?
Are you sure you want to cancel the case creation?
Are you sure you want to close this case
| Products | Region | Phone Numbers |
|---|---|---|
| FlexNet Operations FlexNet Embedded FlexNet Publisher FlexNet Connect FlexNet Code Insight InstallAnywhere InstallShield |
North America * |
+1 630-332-2513 (toll) +1 877-279-2853 (toll-free in North America) |
| Europe * |
+44 1925 944367 (toll) +44 800 047 8642 (toll-free in Europe) |
|
| Japan * | +81 3-4540-5335 (select option 2) | |
| Australia * |
+61 3 9895 2177 +61 1800 560 603 (toll-free in Australia) |
|
|
Usage Intelligence (formerly
Revulytics) Compliance Intelligence |
Please use the Case Portal to submit your support ticket or reach out to your Revenera contact. | |
Revenera Assistant
Case id: 00001065
Activity: Status change: 2 hours ago