While using Cloud Migration/CloudScape, you may encounter the error NT_STATUS_ACCESS_DENIED when attempting to inventory Windows devices. This is a common issue and can usually be resolved by verifying credentials and testing connectivity with WBEMTest.
Step 1: Verify credentials in RN150
- Ensure the credentials entered into the RN150 are correct.
- Re-enter the username and password to confirm there are no typos.
- The account used must be either a Domain Administrator or Local Administrator. Standard user accounts will not work.
Step 2: Test access with WBEMTest
Run WBEMTest from another device in the same network to validate credentials and WMI connectivity.
- On a Windows machine, select Start, type wbemtest, and press Enter.
- In the WBEMTest window, select Connect.
- In the Namespace field, enter:
\\<computer name>\root\cimv2replacing<computer name>with the hostname of the target device. - Enter the administrator account username and password.
- Select Connect.
-
- If authentication is successful, you will see WbemServices, and the tabs will be active.
- If authentication fails, review the error message and follow Microsoft’s guidance on enabling remote WMI access: User Account Control and WMI.
Step 3: Retry the scan in RN150
After resolving authentication issues and confirming successful WBEMTest results, re-enter the credentials in the RN150 and perform a rescan.
Once valid administrator credentials are confirmed and WMI access is enabled, the RN150 will successfully inventory your Windows devices without the NT_STATUS_ACCESS_DENIED error.
Related Articles
Windows Collection - Credential Test Error - NTSTATUS: NT code 0xc002001b 10Number of Views Inventory Errors on All Discovered Devices report may run slowly or timeout 3Number of Views WriteRemoteFileEvidenceMatchCounts import writer step may fail with error: Failed to import inventory devices with error m… 5Number of Views Troubleshoot Windows validation error: NTSTATUS 0x8004100c 35Number of Views Hardware Asset Management dashboard widgets "Inventory devices with duplicate names" and "Devices discovered in past 90 da… 4Number of Views
Hi, I am Reva - Ask me anything.
No new updates
Thanks for the feedback!
Your feedback has been saved.Rate this response:
Add Additional feedback ( Optional )
Are you sure you want to cancel
the case creation?
Are you sure you want to cancel the case creation?
Are you sure you want to close this case
| Products | Region | Phone Numbers |
|---|---|---|
| FlexNet Operations FlexNet Embedded FlexNet Publisher FlexNet Connect FlexNet Code Insight InstallAnywhere InstallShield |
North America * |
+1 630-332-2513 (toll) +1 877-279-2853 (toll-free in North America) |
| Europe * |
+44 1925 944367 (toll) +44 800 047 8642 (toll-free in Europe) |
|
| Japan * | +81 3-4540-5335 (select option 2) | |
| Australia * |
+61 3 9895 2177 +61 1800 560 603 (toll-free in Australia) |
|
|
Usage Intelligence (formerly
Revulytics) Compliance Intelligence |
Please use the Case Portal to submit your support ticket or reach out to your Revenera contact. | |
Revenera Assistant
Case id: 00001065
Activity: Status change: 2 hours ago